Sorry if this is longer than most people are used to - its aimed at people who haven't cleaned their wiring loom earths/grounds - yet. Hopefully useful background info for those that have. The post applies to ALL Aluminium framed Buells but the particulars are given for a Uly (the only Buell I have access to is mine). Its needs additional info about where the grounds on Lightnings S and SS variants and Firebolts are and how many etc. Can an owner of each that knows pls post - jv

A light throttle/low speed/moderate rpm cough or hiccup or misfire or stutter or pop, or whatever you want to call it, is a common problem on XB’s. A big part of the fix is cleaning up the earthing joints from the wiring loom. What is not discussed much is WHY the corrosion causes so much trouble, or HOW to fix it so it doesn’t come back again.

WHY

The basic reason the earth joints corrode is because aluminum is actually a very reactive metal. It only seems unreactive because its covered by a thin film of non-conductive oxide, which must be breached at any electrical joint. Where aluminum touches another metal with a different reactivity (like low reactivity copper, tin, lead or their alloys) in the presence of a bit of moisture, it sets up an electrolytic corrosion cell with its own small voltages, a bit like a thermocouple. Where 2 aluminum surfaces touch and are made to carry a current (like the earth return current from starter motor through the engine and frame), that also promotes corrosion when wet and/or salty.

Using the frame to do double duty, carrying the earth return current as well its other functions, is the way Erik Buell designed the Buell. Electro-chemically, it’s just not a good idea.

In airplanes it can’t be avoided; every ounce matters. They don’t run extra ground wires and don’t normally have corrosion problems, so there must be a way of doing it properly. An RNZAF Avionics Engineer told me earth wires must have a resistance of less than 0.7 Ohm, otherwise stray voltage drops can be set up, that affect control computers and other electronics. Steps on how to do it properly are in the HOW section below.

The bit about ‘...stray voltage drops … that affect control computers…’ is important for the misfire/stutter/hiccups. The ECM reads voltage drops across the various sensors. Most sensors have their own earth return loops in the wiring harness, but 2 sensors do not; the Engine Temperature sensor and the O2 sensor. Both are earthed through the engine.

If there are electrical joints that have high resistance (corroded) or if there are induced voltages, like you get in metal close to induction coils (e.g. the ignition coil mounting bracket), then the ECM reads not only the voltage drop across the sensor, but the additional drop across the dirty joints and/or any addition or subtraction of induced voltage. If this varies (as induced voltages do, or the resistance of dirty joints does when stressed by engine vibration, road bumps etc), then the ECM ‘sees’ the sensor voltage changing and compensates for it.

IT'S THE ECM COMPENSATING FOR THESE VOLTAGE CHANGES THAT CAUSES THE MISFIRES, STUTTERS etc. I believe this is why people swear an earth wire to the ignition coil mount stops misfires, when in any normal electrical wiring sense there is no need for it, as discussed here: https://www.buellxb.com/forum/showthread.php?41712-Grounding-the-coil

Also, electro-chemically, you should not rely on ANY current path through aluminum if you can avoid it. Pure aluminum is a very good conductor of electricity, but its alloys are not. That, plus joints that corrode, is why you shouldn’t run earth return currents through it.

And there are a couple of dodgy joints. You need to disassemble the rear end of the bike to clean the joints between the subframe and the main frame ‘…back to bright metal’, and then they are not easy to protect from road spray. Also, the connection from the subframe to the battery negative cable is shrouded by the cadmium plated steel battery tray. You should remove the battery tray to clean that joint properly, but most people won’t.

You can avoid all these issues by running a thick copper earth cable from the frame side of the braided earth strap, at the top anti-vibration mount above the engine, back to the battery negative terminal.

Pic1 & Pic2

Note the two extra wires in the lug at the anti-vibration mount end in the RH picture above; one runs forward to the earth point on the steering head, and another shorter one, connects to the rear coil mounting bolt.

This means all earth return currents from the rear cylinder head back to the battery are carried through copper wires and solder-covered copper or brass lugs, directly to the lead negative terminal. All these metals have similar reactivity, so no corrosion cells are set up.

The earth return current from the lights, horn and instruments also flow through low reactivity joints and any induced voltage in the coil bracket is quashed. A short wire between the 2 bolted earth points in the left-hand side of the rear subframe as shown below, means other sundry earth return currents, are also routed through low reactivity joints.

All these earth joints are still connected to aluminum, but don’t NEED the aluminum as a current path.

If you were OCD about it, you’d run an earth return from both the Engine Temp and O2 sensors, but engine vibration would be a problem and the above works. However, if you suspect a dud ET or O2 sensor, maybe try earthing it directly before replacing it???


HOW


The Airforce earth bonding method is as follows:
• Clean all contact surfaces with Scotchbrite or ~240 grit sandpaper, back to bright metal.
• Spray all contact surfaces with a cleaner/corrosion inhibitor that “…improves electrical properties”, like CRC 2.26.
• Torque up the joint while the contact surfaces are still wet with the cleaner/corrosion inhibitor.
• Clean off the exterior of the joint with contact cleaner (CRC Brakleen or carb cleaner works too)
• Spray the joint with a waxy corrosion protectant like CRC CPC400, to stop water seeping in and corroding it again.

‘Clean all contact surfaces … back to bright metal’ (e.g. on the braided earth strap) means cleaning:
• the engine and frame surfaces where the joints bolt up (at least on the engine side)
• both sides of each end of the dog-bone link
• the new earth cable lug
• as well as both sides of each end of the braided strap itself.

A tap into the threaded holes and cleaning the underside of bolt heads and their threads and washers is not strictly necessary now, because the bolts and the frame or subframe don’t need to carry any current. Loctite on bolt threads won’t affect joint conductivity either.

I’ve only found 5 earth joints in the standard wiring on a Ulysses:
• Two bolted inside the rear cast subframe,
• One at either end of the braided earth strap between the frame and cylinder head bridging the dog-bone anti-vibration mount above the engine,
• One bolted to the front of the steering head.
• Don’t know if other XB’s have more or less – can someone who knows comment pls

Sizes & lengths of extra cable and wire for a Ulysses are:
• Cable from braided strap to battery negative = 20 - 25mm2 cross section and 29” long (eye centre to eye centre). Check length on other XB’s (shorter frames and/or different subframes).
• Wire to steering head earth bolt = at least 0.75mm2 cross section and 36” long + however much is in the connectors.
• Wire to rear coil mounting bolt = at least 0.75mm2 cross section and 12” long + connectors.
• Wire between subframe earth points = at least 0.75mm2 cross section and 6” long (eye to eye). Check on XB’s with different subframes.
• The cable I used was a 20mm2 earth cable from a small-car wiring loom (free from a wrecker). It already had a brass lug crimped and soldered on, to bolt to the battery. I cut it to length and got an auto electrician to crimp and solder a lug on the other end.

Crimp-on lug:
• get one sized for the cable + 2 extra wires with as big a surface area around the 5/16” hole as you can.
• get it soldered as well as crimped (belt and braces).
• Heat-shrink a sleeve that has glue inside it, over all 3 wires, to strain-relieve the 2 smaller wires so they don’t break from vibration.

Spraying CPC400:
• use cardboard behind the joint to give room to allow the spray to get to the back of the joint and rags or paper to catch the overspray.

Pic 4

• use a heat-gun/hair dryer between coats to flash off the solvent, to build up the film thickness.

Moarant posted this https://www.buellxb.com/forum/showth...ng-(-3500-RPM), (and BadWeb) which shows that doing continuity testing didn't pick up that the earth to the ECM was bad. Through some inspired guesswork he figured the ECM earthing was the problem and added an extra earth wire spliced into the ECM earth leads and running directly to the battery, which cured his problem.
There are 2 possible causes I can think of for this:
1. Since the bike is a Lightning and the ECM earths on the opposite side of the subframe to the battery, that the joint between the sub-frame halves was corroded - fix with a wire between the earth points like on my Uly, or
2.That the crimp on the earthing lug was bad. I measured the resistance of my earth wires from the black ECM plug back to the sub-frame lug and found 7 Ohms resistance, however my misfire was cured by the earth cable and the high resistance crimp didn't seem to be part of that problem. After measuring, I did spray that joint, including the crimp, with CRC2.26 and since then the resistance has been lower every time I've measured it. That could be my poor measuring technique, but might also be the effect of the CRC2.26. I got an electrician with a Fluke DMM to measure it again today and the the resistance is back to near zero (as it should be) - so I won't be changing that crimped lug - but will keep an eye on it.
Whatever be aware that crimps can go bad over time if they weren't made right to start with and be a source of voltage drop, which could cause a misfire like it did for Moarant. You'll only pick them up by measuring their resistance with a sensitive DMM, not by continuity testing.

My ‘07 Ulysses had an intermittent misfire that was 99% fixed by running the earth cable from the braided earth strap to the battery negative and cleaning/corrosion-inhibiting both ends of the braided earth strap joints and both battery terminals as above (the last 1% was fixed by richening the mixture). The extra earth wire to the ignition coil mounting bolt didn’t make any difference on my bike, but probably would have if I hadn’t put in the earth cable and cleaned all the joints. However, because it’s so important to quash stray voltages, which may even be between parts of the engine, I did it anyway. I believe you should too.

In an ideal world, Buell’s stock earth wiring works. But, as many people have found, if the bike starts to misbehave you have to clean the earth connections; the method given will clean and protect the standard wiring loom connections properly. Probably, just applying the Airforce earth bonding process to the standard wiring earth points would be enough in most cases. However, that still won’t improve the joints between the subframe and main frame and may not be enough to suppress induced voltage effects on the Engine Temp and/or O2 sensors. The earth cable from the braided strap, and the earth wire from the coil mount, are effective for this - jv

Pic1

Pic2

Pic3

Pic4
Top of pagePrevious messageNext messageBottom of page Link to this message

John_vreede
Posted on Friday, August 17, 2018 - 01:08 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Find attached a checklist that takes the stuff above and puts it on 2 pages that hopefully you can download - jv
application/pdf
Earths_Grounds Cleaning Checklist .pdf (188.9 k)
Top of pagePrevious messageNext messageBottom of page Link to this message

Mr_obsessive
Posted on Sunday, August 26, 2018 - 11:34 pm:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

A BIG Thank-You for all your data research and pictures!!
Top of pagePrevious messageNext messageBottom of page Link to this message

Tleighbell
Posted on Saturday, September 01, 2018 - 09:13 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

I second that.
Top of pagePrevious messageNext messageBottom of page Link to this message

John_vreede
Posted on Saturday, September 01, 2018 - 08:33 pm:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

NASA and the military have produced documents and MIL-STD's about Galvanic corrosion of metals in electrical contact (which is what earth joint corrosion is).
In an offline discussion, Gabby_duck from BadWeB showed me a NASA paper on electrical bonding (many thanks Alan!).
It has a table showing which metals can be in contact with which, and what to do when they are. (see attached)
The bullet points under the table are good background info - jv
application/pdfTable of Galvanic corrosion between metals
Galvanic corrosion series Table 2 MIL 8998 Dissimilar metals.pdf (158.6 k)
Top of pagePrevious messageNext messageBottom of page Link to this message

Greg_m
Posted on Sunday, September 02, 2018 - 09:59 pm:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Going through the ground connections has been on my list (along with fork seals, wheel bearings, etc. etc. ...) and I was hoping to make it to winter before tackling the project as my work schedule has left me next to no time at home this year. Sure I had to charge the battery more often than I thought reasonable, starting was often reluctant, sometimes the speedo would take time off, the check engine light came on once in a while etc.. But a trip to a local hardware store resulting in the need for a boost forced my hand. And there's only a million or so other chores that need immediate attention so I decided today would be the day.

I followed the tutorial in the first post with only minor adjustments. The whole went smoothly. The bike is running great. The random pop when speed matching on deceleration is gone - I had assumed this had something to do with the inoperable exhaust actuator. Of course the new set of Iridium plugs I put in while I was at it can't hurt. I also put a volt meter where the accessory power outlet had been for good measure.

I'm hoping a good bit of electrical weirdness has been exorcised.


volt meter
« Previous Next »

Add Your Message Here
Post:
Bold text Italics Underline Create a hyperlink Insert a clipart image

Username: Posting Information:
This is a private posting area. Only registered users and custodians may post messages here.
Password:
Options: Post as "Anonymous" (Valid reason required. Abusers will be exposed. If unsure, ask.)
Enable HTML code in message
Automatically activate URLs in message
Action:

Topics | Last Day | Tree View | Search | User List | Help/Instructions | Rules | Program Credits Administration