G oog le BadWeB | Login/out | Topics | Search | Custodians | Register | Edit Profile


Buell Forum » Big, Bad & Dirty (Buell XB12X Ulysses Adventure Board) » BB&D Archives » Archive through June 12, 2010 » Uly oil hotter with comfort kit on 06' « Previous Next »

Author Message
Top of pagePrevious messageNext messageBottom of page Link to this message

Electraglider_1997
Posted on Saturday, June 05, 2010 - 10:31 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

I monitor my oil temp at the swingarm pretty closely. It was in the 90's yesterday and I noticed that the oil was right at 200 F +/- a couple degrees when I would check it. My fan only comes on at shutdown (so far) since fully installing the comfort kit. This seems 5 or 10 degrees hotter than what I remember Before Comfort Kit ( BCK ). I also remember the Buell engineers always claiming that a RSS would keep the fan from coming on but the rear head would be hotter. Anytime BCK the fan would come on if the oil got over 195 F at the swingarm. Not these days. I'm not complaining, just observing. My bike runs like a top, always has. I kind of wish I could turn that fan on with a switch so I could see what effect that would have on my swingarm oil temp. But anyways, so long as that oil temp stabilizes (like it does) I've got no worries.

I think one of the reasons my bike always has run so well is because I rarely clean the thing. The most I do is wipe it off and even that isn't too often. Sometimes I wish I were more of a neat freak but then I'd probably be bitching about corroded 77 connectors and hard to figure out electrical gremlins. My bike is like the dirty kid that never gets sick.
Top of pagePrevious messageNext messageBottom of page Link to this message

Hughlysses
Posted on Saturday, June 05, 2010 - 11:12 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

EG- You could accomplish your experiment as follows: ride a steady pace at a speed that you know won't cause the fan to kick on and monitor oil temp. Pull over and stop with the motor idling long enough for the fan to kick on. Then repeat test at same speed with fan running and monitor oil temperature until it re-stabilizes. That should give you the comparison you're looking for.
Top of pagePrevious messageNext messageBottom of page Link to this message

Teeps
Posted on Saturday, June 05, 2010 - 11:59 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Considering that all heated air, from rear cylinder, is directed at the swing arm/oil tank with the comfort kit. I don't find the observation surprising.
Top of pagePrevious messageNext messageBottom of page Link to this message

Windrider
Posted on Saturday, June 05, 2010 - 12:10 pm:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Electraglider,
The switch to turn on the fan is speed. Any speed > 15MPH and the fan is on once the engine warms up.

So, unless you are stuck in traffic, or climbing goat trails, the fan is running with the comfort kit flash.
Top of pagePrevious messageNext messageBottom of page Link to this message

Hughlysses
Posted on Saturday, June 05, 2010 - 12:48 pm:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Windrider- his Uly is a 2006 model; there's no updated flash available for the 2006 or 2007 models.
Top of pagePrevious messageNext messageBottom of page Link to this message

Rr_eater
Posted on Sunday, June 06, 2010 - 02:59 pm:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

I have pondered this exact issue with my 06. How can I get the fan to come on anytime I am moving, in lets say, low speed mode, since as has been noticed before, the fan blade is a restriction to air flow when not spinning.

I have a couple ideas, seeing as how the fan is always powered, just gets a switched ground from the ECM that switches slowly for low speed, and faster for high speed.

I could build a switched circuit with a relay system so as not to feed ground back to the ecm.

Hmmmmmmm

Bruce
Top of pagePrevious messageNext messageBottom of page Link to this message

Snojet
Posted on Sunday, June 06, 2010 - 03:14 pm:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Rr_eater,
I've been thinking of the same thing, I have an 06. But I'm sort of lazy, and I'll eventually get to.
If you beat me to it, please post results/how-to.
I was thinking about some type of rheostat control, but I haven't done any further looking into this.
Top of pagePrevious messageNext messageBottom of page Link to this message

Rr_eater
Posted on Sunday, June 06, 2010 - 05:37 pm:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

The primary trick to this is disconnecting the ECM from the circuit while utilizing it, at the same time letting the ECM control normal operation, that is the catch for me right now.

Bruce
Top of pagePrevious messageNext messageBottom of page Link to this message

Methed
Posted on Monday, June 07, 2010 - 03:04 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Instead of bypassing the fan, would the mounting of a second fan wired as such be a potential solution? I know very well how limited space is in this area, however you could stack the fans (pending clearance) and the added air pressure would definitely keep the blades on either moving when the other is in operation. I would think that matching RPMs or output on a two-fans-stacked setup might need to be considered.

(Message edited by methed on June 07, 2010)
Top of pagePrevious messageNext messageBottom of page Link to this message

Snojet
Posted on Monday, June 07, 2010 - 12:27 pm:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Methed,
I like the idea but I don't think there is enough room. When I did my O2 sensor things are real tight.

Rr_eater,
I need to get with my more advanced electrician friends and see if there is a sort of disconnect that we could put in the harness to take the ECM out and then manually control the fan. Once we are done manually controlling the fan, then reconnecting the ECM, so it will take over. Is this possible or am I reaching here?
Top of pagePrevious messageNext messageBottom of page Link to this message

Rr_eater
Posted on Tuesday, June 08, 2010 - 03:42 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

No, it is possible. Working it right now!!

LYK

Bruce
Top of pagePrevious messageNext messageBottom of page Link to this message

Yamafreak
Posted on Tuesday, June 08, 2010 - 07:44 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

I saw a post with a switch on the bar's but now I can't find it.
Top of pagePrevious messageNext messageBottom of page Link to this message

Rr_eater
Posted on Wednesday, June 09, 2010 - 01:15 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Yeah, you could just switch a ground to the fan, but then you are back feeding a ground to the ECM when it is not called for. Also the fan would run full speed all the time, most likely not a big deal when it is hot though.....
Top of pagePrevious messageNext messageBottom of page Link to this message

Froggy
Posted on Wednesday, June 09, 2010 - 01:24 am:   Edit Post Delete Post View Post/Check IP Print Post    Move Post (Custodian/Admin Only) Ban Poster IP (Custodian/Admin only)

Doing that ground out will throw a trouble code and cause the check engine light to come on.
« Previous Next »

Add Your Message Here
Post:
Bold text Italics Underline Create a hyperlink Insert a clipart image

Username: Posting Information:
This is a private posting area. Only registered users and custodians may post messages here.
Password:
Options: Post as "Anonymous" (Valid reason required. Abusers will be exposed. If unsure, ask.)
Enable HTML code in message
Automatically activate URLs in message
Action:

Topics | Last Day | Tree View | Search | User List | Help/Instructions | Rules | Program Credits Administration